Chat with us, powered by LiveChat

Secure Checkout
Glass Fiber Syringe Filters, 2.7 um, 33mm, Double Luer-Lok, Nonsterile, 100/Pk

Thumbnail Filmstrip of Glass Fiber Syringe Filters, 2.7 um, 33mm, Double Luer-Lok, Nonsterile, 100/Pk Images

    Purchase Glass Fiber Syringe Filters, 2.7 um, 33mm, Double Luer-Lok, Nonsterile, 100/Pk

    Glass Fiber Syringe Filters, 2.7 um, 33mm, Double Luer-Lok, Nonsterile, 100/Pk
    Tisch SKU: SPEC20235

    $194.95
    4 in stock. Additional units ship in 4 weeks.
     

    Tisch Scientific Glass Fiber (GF) Syringe Filters, 2.7 µm, 33 mm, 100/Pk - SPEC20235

    Tisch Scientific's product lineup extends from filtration membranes to devices and the consumable supplies laboratories use daily. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. Glass fiber captures particulates throughout its depth for high loading capacity and resists chemical attack across diverse solvents. The creep-resistant MBS matrix stays pressed firmly to the membrane while absorbing handling stress at the bench and tolerates aqueous acids, bases, and alcohols during standard prep. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.

    Membrane Characteristics

    • Randomly oriented fiber network creates multiple particle interception paths
    • Extends filterable sample volume three to seven times versus unprotected media
    • Glass microfiber matrix maintains stable flow characteristics under differential pressure
    • Surface silanol groups attract water molecules for immediate aqueous wetting
    • Silanol groups on borosilicate fiber surfaces provide inherent chemical reactivity

    Housing Characteristics

    • Phthalate-free composition keeps a common LC-MS and GC-MS contaminant out of sample workflows
    • Bisphenol-A-free composition keeps background signal out of trace-level BPA and endocrine-disruptor testing
    • Hard methacrylate surface resists scuffing through repeated handling
    • Luer-compatible MBS housing connects directly to standard syringe tips for hand-pressure filtration

    Juggling several filter types for one routine clarification eats up your bench time. Consistent aqueous clarification clears particulates without slowing your bench routine the same way every time you run it. Request a quality certificate, lot documentation, or a blanket-order quote for your filtration order at any time.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Connection Type
    Double Luer Lock
    Construction
    Methacrylate Butadiene Styrene (MBS)
    Diameter
    33mm
    Filtration Area
    4.6cm²
    Holdup Volume
    200µl
    Material
    Glass Fiber (GF)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    250-290µm
    Pack Count
    100
    Pore Size (µm)
    2.7
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Sterilization
    Autoclave 121°C for 30min/ gamma 25kGy
    Volume Throughput (ml)
    110ml
    Weight
    0.96
    Wettability
    Hydrophilic
    • QuEChERS Extract Prep - Clarifies lipid-laden produce extracts ahead of GC-MS pesticide residue analysis, preventing analytical column fouling.
    • Bioanalytical Prep - Clears precipitated plasma and serum proteins ahead of LC-MS/MS assay, protecting columns and autosampler needles.
    • Cannabis Extract Analysis - Glass fiber removes lipid and plant wax particulates from cannabis extracts ahead of cannabinoid potency testing.
    • Tissue Culture - Clarifies tissue homogenates and cell lysates with ease, protecting finer downstream membranes from early blockage.
    • Dissolution Testing - Clarifies pharmaceutical dissolution media of excipient particulates, protecting HPLC and UV assay systems from column fouling.
    • Milk and Dairy Analysis - Glass fiber prefiltration removes casein and fat globules from dairy samples ahead of HPLC and ion chromatography.