    Whatman Puradisc Water-Wettable PTFE Syringe Filters, 0.2 µm, 25 mm, 1000/Pk - 6774-2502

    Whatman has built such a strong track record in published methods that laboratories default to citing its name in standardized protocols. A sterilizing-grade syringe filter carries manufacturer bacterial retention testing built into the design, giving analysts documented sterile-grade performance without repeating that testing in-house for the format. PTFE carries the lowest surface energy among fluoropolymer membranes, limiting protein adhesion and filters aqueous and organic samples in one membrane. The polypropylene housing routes flow to minimize backpressure in service and presses snugly against the membrane during the pass. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.

    Membrane Characteristics

    • Retention meets the Brevundimonas diminuta challenge standard for a 7-log reduction
    • The membrane's chemical compatibility extends to aggressive organic solvents beyond aqueous solutions
    • Absolute-rated pore structure delivers repeatable particle capture batch to batch
    • The fluoropolymer's broad thermal stability withstands autoclave temperatures up to 134°C
    • The fluoropolymer's chemical inertness keeps proteins stable in solution

    Housing Characteristics

    • The seal formed against the membrane blocks bypass at rated operating pressure
    • Plasticizer-free polyolefin construction keeps the fluid path clean
    • Rigid polypropylene body maintains its geometry through routine filtration pressure
    • Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics

    An unfiltered buffer can foul your instrument and interrupt a run mid-sequence. Reliable particulate removal protects your instruments and your data across reagent, buffer, and mobile-phase preparation. Request Whatman's quality documentation to support your filtration step meeting a recognized laboratory-science standard.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    1.0 bar (15 psi) [IPA]
    Burst Pressure (psi)
    75psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    Polypropylene
    Diameter
    25mm
    Filtration Area
    4.2cm²
    Flow Rate
    ~20 (MeOH)
    Holdup Volume
    <100µl
    Material
    Hydrophilic Polytetrafluoroethylene (PTFE)
    Maximum Operating Pressure
    75psi
    Maximum Operating Temperature (°C)
    121°C
    Pack Count
    1000
    Pore Size (µm)
    0.2
    Prefilter (Yes/No)
    No
    Sterility
    Nonsterile
    Sterilization
    Autoclavable 121°C
    Volume Throughput (ml)
    Up to 100ml
    Wettability
    Hydrophobic
    • Clinical Chemistry Prep - Prepares serum and plasma filtrates in mixed aqueous and organic media for routine clinical analyzer instruments.
    • Universal HPLC Prep - A single filter handles both aqueous and organic mobile phases, removing the need for alcohol pre-wetting before injection.
    • Mobile Phase Degassing - Provides a chemically inert barrier that withstands aggressive solvents used in high-sensitivity gradient chromatography.
    • Plasma Protein Crash - Clarifies acetonitrile protein-precipitation supernatants from bioanalytical plasma samples for PK profiling by LC-MS.
    • Peptide Sample Prep - Clarifies tryptic digest solutions in acetonitrile and formic acid ahead of nano-LC-MS peptide sequencing analysis.
    • LC-MS Sample Prep - Minimizes membrane-derived extractables that can suppress ionization or add background peaks in mass spectrometry detection.