Whatman Puradisc Water-Wettable PTFE Syringe Filters, 0.2 µm, 25 mm, 200/Pk - 6773-2502
Whatman has built such a strong track record in published methods that laboratories default to citing its name in standardized protocols. At the sub-micron pore rating, a syringe filter delivers sterilizing-grade retention at the point of use. The hydrophilic PTFE membrane resists strong acids, alkalis, and organic solvents while limiting the hydrophobic interactions that draw proteins and yields sterility-grade output across its finest pore ratings. Polypropylene construction maintains a low-dead-volume internal flow path while pressing snugly against the membrane during the pass and holds its geometry through sample filtration at temperatures up to 121°C. For workflows requiring validated sterile-grade performance, point-of-use retention meets it without a separate sterilization step.
Membrane Characteristics
- Absolute-rated pore structure delivers repeatable particle capture batch to batch
- The fluoropolymer's broad thermal stability withstands autoclave temperatures up to 134°C
- Retention meets the Brevundimonas diminuta challenge standard for a 7-log reduction
- Minimal extractable material leaches from the membrane during use
- The fluorocarbon backbone's carbon-fluorine bonds rank among the strongest in organic chemistry
Housing Characteristics
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
- Plasticizer-free polyolefin construction keeps the fluid path clean
- Stable across the full aqueous pH range in routine sample work
- Impact-tolerant polypropylene body withstands routine bench handling without damage
A particulate-laden aqueous sample makes the rest of your preparation unpredictable. Consistent aqueous clarification clears particulates without slowing your bench routine across the buffers and reagents your day-to-day prep depends on. Request volume pricing and stock availability on your filtration product selection from the Tisch Scientific team.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 1.0 bar (15 psi) [IPA]
- Burst Pressure (psi)
- 75psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polypropylene
- Diameter
- 25mm
- Filtration Area
- 4.2cm²
- Flow Rate
- ~20 (MeOH)
- Holdup Volume
- <100µl
- Material
- Hydrophilic Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 200
- Pore Size (µm)
- 0.2
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 100ml
- Wettability
- Hydrophobic
- Pharmaceutical API Testing - Filters active ingredient solutions in mixed aqueous and organic solvents for potency assay and impurity profiling.
- Forensic Toxicology Prep - Clarifies urine, blood, and tissue extracts containing organic solvents for confirmatory LC-MS drug screening.
- Small Molecule Recovery - Limits analyte loss when filtering low-concentration pharmaceutical compounds thanks to its low-binding surface chemistry.
- UPLC Sample Clean-up - Supports high-pressure chromatography with a low-extractable membrane that keeps UV-absorbing background to a minimum.
- Universal HPLC Prep - A single filter handles both aqueous and organic mobile phases, removing the need for alcohol pre-wetting before injection.
- Clinical Chemistry Prep - Prepares serum and plasma filtrates in mixed aqueous and organic media for routine clinical analyzer instruments.