Whatman Puradisc Water-Wettable PTFE Syringe Filters, 0.45 µm, 25 mm, 50/Pk - 6772-2504
Whatman maintains in-house specialists who set and verify material specifications separately for its cellulose, glass-fiber, and polymer membrane chemistries, tailoring quality control to how each one behaves in use. Sample preparation for chromatography often ends with a syringe filter on the path to the vial. PTFE's naturally low surface energy is overcome by chemical treatment and keeps fluoropolymer surface indifferent to protein in solution. The PP housing sustains efficient flow on viscous samples while holding its seal true run after run and stays inert across common laboratory solvents. Where small-volume samples must reach the instrument clean, low hold-up volume keeps sample loss minimal while the instrument stays protected from particulate damage.
Membrane Characteristics
- The membrane's chemical compatibility extends to aggressive organic solvents beyond aqueous solutions
- The fluorocarbon backbone's carbon-fluorine bonds rank among the strongest in organic chemistry
- Absolute-rated pore structure delivers repeatable particle capture batch to batch
- The membrane turns optically clear on contact with water, confirming full wetting
- Minimal extractable material leaches from the membrane during use
Housing Characteristics
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
- The seal formed against the membrane blocks bypass at rated operating pressure
- Plasticizer-free polyolefin construction keeps the fluid path clean
- Housing tolerates elevated-temperature aqueous and solvent sample filtration up to about 80°C without softening
A particulate-laden aqueous sample makes the rest of your preparation unpredictable. General-purpose aqueous filtration supports the sample types you handle every day so you can standardize one filter across most aqueous methods. Standardize your filtration purchases across every method with volume pricing and documentation from the Tisch Scientific team.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 0.6 bar (9 psi) [IPA]
- Burst Pressure (psi)
- 75psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polypropylene
- Diameter
- 25mm
- Filtration Area
- 4.2cm²
- Flow Rate
- ~30 (MeOH)
- Holdup Volume
- <100µl
- Material
- Hydrophilic Polytetrafluoroethylene (PTFE)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 50
- Pore Size (µm)
- 0.45
- Prefilter (Yes/No)
- No
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 100ml
- Wettability
- Hydrophobic
- Clinical Chemistry Prep - Prepares serum and plasma filtrates in mixed aqueous and organic media for routine clinical analyzer instruments.
- Cannabinoid Potency Testing - Clarifies cannabis and hemp extracts before HPLC quantitation, giving low analyte adsorption for accurate recovery.
- Agricultural Herbicide Prep - Handles acetonitrile and ethyl acetate extracts from crop and soil matrices for multi-residue herbicide testing.
- Forensic Toxicology Prep - Clarifies urine, blood, and tissue extracts containing organic solvents for confirmatory LC-MS drug screening.
- Polymer Additive Analysis - Clarifies THF and chloroform additive extracts for HPLC profiling of polymer stabilizers and plasticizers.
- Pharmaceutical API Testing - Filters active ingredient solutions in mixed aqueous and organic solvents for potency assay and impurity profiling.