Whatman GD/X Polyethersulfone (PES) Syringe Filters, 0.2 µm, 25 mm, 50/Pk - 6896-2502
Whatman stages multiple glass fiber layers inside the GD/X cartridge to intercept particles in progressive steps, leaving only the smallest fraction to reach the tightly rated final membrane. A sterilizing-grade syringe filter carries manufacturer bacterial retention testing built into the design, giving analysts documented sterile-grade performance without repeating that testing in-house for the format. PES provides sterile-grade retention at the rated sub-micron pore size while loading aqueous buffers with zero pre-wetting delay and pairs fast flow with reduced protein adsorption. Polypropylene construction maintains a low-dead-volume internal flow path while sustaining structural integrity through elevated-temperature filtration operations and is supplied pre-sterilized in individual packaging for sterile sample preparation. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.
Prefiltration
- Two-stage construction pairs a glass microfiber depth prefilter with the final membrane
- Upstream glass microfiber prefilter layer captures coarse particulate ahead of the membrane
- Nominal glass microfiber depth layer sustains flow through high-solids, particle-laden samples
- Glass microfiber depth media loads particulate across its full thickness
Membrane Characteristics
- Non-ionic surface avoids charge-driven protein binding of positively and negatively charged membrane types
- PFAS extractables test non-detectable under EPA Method 537.1
- Chemical breadth spans alcohols, glycols, and aqueous buffers
- Sterilizing-grade PES membrane lots are challenge-tested against Brevundimonas diminuta to qualify 0.2 micron retention
- Pore structure integrity holds through autoclave cycles up to 126°C
Housing Characteristics
- Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
- The seal formed against the membrane blocks bypass at rated operating pressure
- Withstands ethylene oxide gas sterilization without embrittlement or structural damage
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
An unfiltered buffer can foul your instrument and interrupt a run mid-sequence. Upstream buffer clarification keeps your run from stalling on particulates that slipped through while keeping the filtrate analytically clean. Request a quote on Whatman filtration products from the Tisch Scientific team.
Sterilization Guidance
Sterile single-use packaging removes any in-lab sterilization preparation step.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 3.4 bar (50 psi)
- Burst Pressure (psi)
- 75psi
- Connection Type
- Luer-Lok/ Luer Slip
- Construction
- Polypropylene
- Diameter
- 25mm
- Filtration Area
- 4.6cm²
- Flow Rate
- 46
- Holdup Volume
- 1.4ml
- Material
- Polyethersulfone (PES)
- Maximum Operating Pressure
- 75psi
- Maximum Operating Temperature (°C)
- 121°C
- Pack Count
- 50
- Pore Size (µm)
- 0.2
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- Glass Microfiber (GMF)
- Sterility
- Nonsterile
- Sterilization
- Autoclavable 121°C
- Volume Throughput (ml)
- Up to 100ml
- Wettability
- Hydrophilic
- Content Uniformity - Clarifies dense pharmaceutical samples easily, ensuring consistent results in uniformity testing without filter blockage.
- Tissue Processing - Prepares biological tissue homogenates smoothly, managing high protein and cellular debris for cleaner downstream analysis.
- Media Preparation - Facilitates rapid sterilization of tissue culture additives, lowering contamination risk during sensitive laboratory work.
- Sample Recovery - Minimizes sample loss in low-protein-binding applications, delivering high yield for precious or rare biological specimens.
- Nucleic Acid Recovery - Processes DNA and RNA extracts with minimal nucleic acid adsorption, preserving yield on the hydrophilic PES surface.
- PFAS Water Testing - PES filters process aqueous samples for EPA Method 1633A PFAS testing without added fluorinated background.